Header Ads Widget

[MAN] sane-p5

Content-type: text/html; charset=UTF-8 Man page of sane-p5

sane-p5

Section: SANE Scanner Access Now Easy (5)
Updated: 15 Feb 2010
Index Return to Main Contents
 

NAME

sane-p5 - SANE backend for the Primax PagePartner  

DESCRIPTION

The sane-p5 library implements a SANE (Scanner Access Now Easy) backend that provides access to the Primax PagePartner parallel port sheet fed scanner.

This backend handles 100, 150, 200, 300 and 600 dpi scan resolutions, in color and gray modes. The 600 dpi is actually 300x600 with lines enlarged to match the vertical resolution.

EPP/ECP MODES ONLY The current version of the backend uses only EPP or ECP mode to communicate with the scanner. It is recommended that you set your parallel port to EPP in BIOS with the current version of this backend. ECPEPP will only work if you use a 2.4 or 2.6 kernel with ppdev character device support.

 

DEVICE NAMES

This backend expects device names of the form:

port value

Where value is :

auto
autodetect all parallel ports and probe them for scanner
/dev/parport0
uses linux ppdev device, depending on the number of available parallel port, you have to use /dev/parport1, /dev/parport2, ...

You can rename any device using the


option name my_name

option. This option apply to the last port option.

 

CONFIGURATION

Please make sure to edit dll.conf before you use the backend, since this backend isn't enabled by default.

 

FILES

@CONFIGDIR@/p5.conf
The backend configuration file (see also description of SANE_CONFIG_DIR below).
@LIBDIR@/libsane-p5.a
The static library implementing this backend.
@LIBDIR@/libsane-p5.so
The shared library implementing this backend (present on systems that support dynamic loading).

 

ENVIRONMENT

SANE_CONFIG_DIR
This environment variable specifies the list of directories that may contain the configuration file. Under UNIX, the directories are separated by a colon (`:'), under OS/2, they are separated by a semi-colon (`;'). If this variable is not set, the configuration file is searched in two default directories: first, the current working directory (".") and then in @CONFIGDIR@. If the value of the environment variable ends with the directory separator character, then the default directories are searched after the explicitly specified directories. For example, setting SANE_CONFIG_DIR to "/tmp/config:" would result in directories "tmp/config", ".", and "@CONFIGDIR@" being searched (in this order).
SANE_DEBUG_P5
If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 255 requests all debug output to be printed. Smaller levels reduce verbosity.

level   debug output
------- ------------------------------
 0       critical errors
 1       errors
 2       warnings & minor errors
 4       information messages
 8       start/stop of functions
 16      tracing messages              
 32      I/O functions
 64      I/O functions with traces
 128     scanned/calibration data


 

 

SEE ALSO

sane(7), sane-net(5), saned(8)

 

AUTHOR

Stéphane Voltz <stef.dev@free.fr>

 

CREDITS

Support for the Prima PagePartner has been made possible thank to an hardware donation by Sébastien Lange.

 

BUG REPORTS

If something doesn't work mail sane-devel@lists.alioth.debian.org or use the bug tracker at https://alioth.debian.org/tracker/?atid=410366&group_id=30186 . Please give as much information as you can.

SANE version
run "scanimage -V" to determine this
the backend version and your scanner hardware
run "SANE_DEBUG_P5=255 scanimage -L 2>log" as root. If you don't get any output from the p5 backend, make sure a line "p5" is included into your @CONFIGDIR@/dll.conf. If your scanner isn't detected, make sure you've defined the right port address, or the correct device in your p5.conf.
the name of your scanner/vendor
also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
any further comments
if you have comments about the documentation (what could be done better), or you think I should know something, please include it.


 

Index

NAME
DESCRIPTION
DEVICE NAMES
CONFIGURATION
FILES
ENVIRONMENT
SEE ALSO
AUTHOR
CREDITS
BUG REPORTS

This document was created by man2html, using the manual pages.
Time: 04:45:55 GMT, September 16, 2022

댓글 쓰기

0 댓글